You Are Here: HOME>Security>Detectors>Vibration Detector > SC-100 / SC-105

SC-100 / SC-105

Seismic Vibration Sensors

  • Detects attacks from
  • Compact size
  • Universal (ATM and vault)
  • Drilling shield (standard)
  • Extended temperature
  • Remote sensitivity reduction input
  • Multi-compatible mounting plate fits on pre-fab holes
  • Integrated End-of-Line (EOL) resistors
  • Integrated temperature alarm
Detects attacks on Bank vault doors, ATMs, night deposit safes, strong room vaults, modular vaults, vending machines, freestanding safes, hatches, gates, chests and other objects with a solid structure
Detects attacks from
- Heavy strokes or gross attacks from sledgehammers or explosives
- Repeated knocks from hammers and chisels
- Drilling, mechanical cutting, acetylene torches, thermal cutting, water-cooled diamond drills, water jet cutting tools, hydraulic jacks (SC100 only)
Compact size Smallest available on market so fits easier when space is limited
Universal (ATM and vault) The SC100 can also be used for ATMs and night deposit safes by the simple change of a dip switch. No separate sensors are required.
Drilling shield (standard) Protects electronics inside against sabotage
Extended temperature Allows operation in extreme temperature conditions (-40° F to 158° F)
Remote sensitivity reduction input Option to reduce sensor sensitivity remotely during maintenance on ATMs, thereby reducing false alarms
Multi-compatible mounting plate fits on pre-fab holes Fits on most pre-drilled mounting holes from other seismic sensors, preventing time consuming drilling/threading. The same mounting plate can be used for mounting on concrete and welding on steel.
Integrated End-of-Line (EOL) resistors EOL resistors for alarm as well as tamper loop are already incorporated, saving installation time and reducing service calls
Integrated temperature alarm The SC100 and SC105 will alarm if the temperature exceeds 185° F. Additionally the SC100 version alarms when temperature rises faster than 6° F per minute.
Diagnostic LED Built-in tool easily selects correct sensitivity; no time consuming external tools required
Selectable sensitivity Four different sensitivity settings adapt to required range and environmental conditions
Remote testing and test transmitters Input to remotely start functional test with help of SC113 (Internal Test Transmitter) or SC115 (External Test Transmitter). If no test transmitter is available, it is possible to test internal electronics with this test.

Available accessories Mounting plate, keyhole protection kit, day/night kit, Internal Test Transmitter, armed cable and External Test Transmitter. This range of accessories allows the SC100 and SC105 Seismic Sensors to be mounted in a wide range of applications.

Specifications

SC100

SC105

Power Requirements

Supply Voltage

8 ~ 16 VDC, nominal 12 VDC

Current Consumption

Typical 3 mA @ 12 VDC

Sensitivity

Adjustable Sensitivity

4 levels by DIP Switches

ATMs / Vault selection

by DIP switch

N/A

Delayed triggering

N/A

by DIP switch

Reduced Sensitivity Input

For maintenance & Service: Active low (<1.5 VDC)

Detection Radius

5m

3m

Alarm algorithm

Highly sensitive to all known attacks while rejecting known false alarm sources by innovative filters and firmware

Equal to SC100 but adapted to higher environmental noise of public areas where protected objects mainly are installed to prevent unwanted alarms

Alarm Outputs

Solid State Relay (Change Over)

30 VDC / 100 mA; Type C

30 VDC / 100 mA; Type A

Open Collector

Active low during alarm

Alarm Hold Time

Approx. 2.5 sec

Sabotage Protection

Pry-off and Cover Switch

30 VDC / 100 mA

Low Supply Voltage Alarm *

< 7 VDC

Temperature Alarm *

+85°C ± 5°C

Internal Functional Alarm*

Stainless steel drill shield

Inputs

Remote test

Active low 1.5 VDC, test duration < 0.5 sec

Reduced Sensitivity Input

Active low 1.5 VDC, test duration < 0.5 sec Sensitivity reduction to 12.5 %

Installation Tool

A noise and alarm indicator is incorporated to support sensitivity setting.

Environmental Conditions

Maximum Humidity

95% RH (non-condensing)

Operation Temperature

-40°C ~ + 70°C

Storage Temperature

-50°C ~ + 70°C

Environmental Class (VdS)

III

Housing Protection Category

IP43

Housing

Dimensions (H x W x D)

80 mm x 60 mm x 21 mm

Chassis and Cover

Die-cast metal

Color

RAL7035 (light grey)

Weight

0.228kg